Following is the requirements for EN 61000-6-1

Immunity - Enclosure port

1

Environmental
Phenomena

Test
Specification

Units

Basic
Standard

Remarks

Performance
Criteria

1.1 Power-frequency
magnetic field.
50
3
Hz
A/m
EN 61000-4-8 See note
1 & 2
A
1.2 Radio-frequency
electromagnetic field.
Amplitude Modulated.
80-1000
3
80
MHz
V/m
%AM (1kHz)
EN 61000-4-3 The test level specified is the rms value of the unmodulated carrier. A
1.3 Radio-frequency
electromagnetic field.
Keyed carrier.
900 ± 5
3
50
200
MHz
V/m
Duty cycle %
Rep. frequency Hz
EN 61000-4-3 The test level specified is prior to keying. The test shall be carried out at one frequency within the indicated range. A
1.4 Electrostatic discharge. ± 4 Contact
discharge

± 8 Air
discharge

kV (charge voltage)

kV (charge voltage)

EN 61000-4-2 See basic standard for applicability of contact and/or air discharge test. B

B

bulletNOTE 1: Applicable only to apparatus containing devices susceptible to magnetic fields, such as Hall elements, electrodynamic microphones, magnetic field sensors, etc.
bullet

NOTE 2: For CRTs the acceptable jitter depends upon the character size and is computed for a test level of 1A/m as follows:
jitter (mm) = (3 x character size (mm) + 1)/40.
As jitter is linearly proportional to the magnetic field strength, tests can be carried out at other test levels extrapolating the maximum jitter level appropriately.

Immunity - Ports for signal lines and control lines

2

Environmental
Phenomena

Test
Specification

Units

Basic
Standard

Remarks

Performance
Criteria

2.1 Radio-frequency
common mode.
0.15-80
3
80
MHz
V rms
%AM (1kHz)
EN 61000-4-6 See notes 1 & 2.
The test level specified is the rms value of the unmodulated carrier.
A
2.2 Fast transients ± 0.5
5/50
5
kV (charge voltage)
Tr/Th ns
Rep. frequency kHz
EN 61000-4-4 See note 2.
Capacitive clamp used.
B
bulletNOTE 1: The test level can also be defined as the equivalent current into a 150 ohm load.
bullet

NOTE 2: Applicable only to ports interfacing with cables whose total length according to the manufacturers functional specification may exceed 3 m.

Immunity - DC input and DC output power ports

3

Environmental
Phenomena

Test
Specification

Units

Basic
Standard

Remarks

Performance
Criteria

3.1 Radio-frequency
common mode.
0.15-80
3
80
MHz
V rms
%AM (1kHz)
EN 61000-4-6 See notes 1 & 2.
The test level specified is the rms value of the unmodulated carrier.
A
3.2 Fast transients ± 0.5
5/50
5
kV (charge voltage)
Tr/Th ns
Rep. frequency kHz
EN 61000-4-4 See note 3. B
3.2 Surges
line to ground
line to line
1.2/50 (8/20)
± 0.5
± 0.5
Tr/Th µs
kV (charge voltage)
kV (charge voltage)
EN 61000-4-5 See note 3. B
bulletNOTE 1: The test level can also be defined as the equivalent current into a 150 ohm load.
bulletNOTE 2: Applicable only to ports interfacing with cables whose total length according to the manufacturers functional specification may exceed 3 m.
bullet

NOTE 3: Not applicable to input ports intended for connection to a battery or a rechargeable battery which must be removed or disconnected from the apparatus for recharging. Apparatus with a DC power input port intended for use with an AC-DC power adapter shall be tested on the AC power input of the AC-DC power adapter specified by the manufacturer or where none is so specified using a typical AC-DC power adapter. The test is applicable to DC power input ports intended to be connected permanently to cables longer than 10 m.

Immunity - input and output AC power ports

4

Environmental
Phenomena

Test
Specification

Units

Basic
Standard

Remarks

Performance
Criteria

4.1 Radio-frequency
common mode.
0.15-80
3
80
MHz
V rms
%AM (1kHz)
EN 61000-4-6 The test level specified is the rms value of the unmodulated carrier.
See note 1.
A
4.2 Fast transients ± 1
5/50
5
kV (charge voltage)
Tr/Th ns
Rep. frequency kHz
EN 61000-4-4 - B
4.3 Surges
line to ground
line to line
1.2/50 (8/20)
± 2
± 1
Tr/Th µs
kV (charge voltage)
kV (charge voltage)
EN 61000-4-5 See note 2. B
4.4 Voltage dips 30
10

60
100

% reduction
ms

% reduction
ms

EN 61000-4-11 Voltage shift at zero crossing

See note 2.

B

C

4.5 Voltage interruptions >95 %
5000
% reduction
ms
EN 61000-4-11 Voltage shift at zero crossing
See note 2.
C
bulletNOTE 1: The test level can also be defined as the equivalent current into a 150 ohm load.
bullet

NOTE 2: Applicable only to input ports.

Immunity - Functional earth ports

5

Environmental
Phenomena

Test
Specification

Units

Basic
Standard

Remarks

Performance
Criteria

5.1 Radio-frequency
common mode.
0.15-80
3
80
MHz
V rms
%AM (1kHz)
EN 61000-4-6 See notes 1.
The test level specified is the rms value of the unmodulated carrier.
A
5.2 Fast transients ± 0.5
5/50
5
kV (charge voltage)
Tr/Th ns
Rep. frequency kHz
EN 61000-4-4 See note 2.
Capacitive clamp used.
B
bulletNOTE 1: The test level can also be defined as the equivalent current into a 150 ohm load.
bullet

NOTE 2: Applicable only to ports interfacing with cables whose total length according to the manufacturers functional specification may exceed 3 m.