Following is the requirements for EN
61000-6-2
Immunity - Enclosure port
| 1 |
Environmental
Phenomena |
Test
Specification |
Units |
Basic
Standard |
Remarks |
Performance
Criteria |
| 1.1 |
Radio-frequency
electromagnetic field.
Amplitude Modulated. |
80-1000
10
80 |
MHz
V/m (unmodulated, rms)
%AM (1kHz) |
EN 61000-4-3 |
See note 1. The test level
specified is prior to modulation. |
A |
| 1.2 |
Power-frequency
magnetic field. |
50
30 |
Hz
A(rms)/m |
EN 61000-4-8 |
See note
2 and 3 |
A |
| 1.3 |
Electrostatic discharge. |
± 4 Contact
discharge± 8 Air
discharge |
kV (charge voltage) kV (charge voltage) |
EN 61000-4-2 |
See basic standard for
applicability of contact and/or air discharge test. |
B
B
|
Immunity - Signal ports
| 2 |
Environmental
Phenomena |
Test
Specification |
Units |
Basic
Standard |
Remarks |
Performance
Criteria |
| 2.1 |
Radio-frequency
common mode. |
0.15-80
10
80 |
MHz
V (rms, unmodulated)
%AM (1kHz) |
EN 61000-4-6 |
See notes 1, 2 & 3.
The test level specified is rms value of the unmodulated carrier. |
A |
| 2.2 |
Fast transients |
± 1
5/50
5 |
kV (peak)
Tr/Th ns
Rep. frequency kHz |
EN 61000-4-4 |
See note 3.
Capacitive clamp used. |
B |
| 2.3 |
Surges
line-to-earth |
1.2/50 (8/20)
± 1 |
Tr/Th us
kV |
EN 61000-4-5 |
See notes 4 and 5 |
B |
Immunity - Input and output DC power ports
| 3 |
Environmental
Phenomena |
Test
Specification |
Units |
Basic
Standard |
Remarks |
Performance
Criteria |
| 3.1 |
Radio-frequency
common mode. |
0.15-80
10
80 |
MHz
V (rms, unmodulated)
%AM (1kHz) |
EN 61000-4-6 |
See notes 1 and
2.
The test level specified is rms value of the unmodulated carrier. |
A |
| 3.2 |
Fast transients |
± 2
5/50
5 |
kV (peak)
Tr/Th ns
Rep. frequency kHz |
EN 61000-4-4 |
See note 3. |
B |
| 3.3 |
Surges
line-to-earth
line-to-line |
1.2/50 (8/20)
± 0.5
± 0.5 |
Tr/Th us
kV
kV |
EN 61000-4-5 |
See note 3. |
B |
Immunity - Input and output AC power ports
| 4 |
Environmental
Phenomena |
Test
Specification |
Units |
Basic
Standard |
Remarks |
Performance
Criteria |
| 4.1 |
Radio-frequency
common mode. |
0.15-80
10
80 |
MHz
V rms
%AM (1kHz) |
EN 61000-4-6 |
See note 1
and 2.
The test level
specified is the rms value of the unmodulated carrier. |
A |
| 4.2 |
Fast transients |
± 2
5/50
5 |
kV (charge voltage)
Tr/Th ns
Rep. frequency kHz |
EN 61000-4-4 |
- |
B |
| 4.3 |
Surges
line to earth
line to line |
1.2/50 (8/20)
± 2
± 1 |
Tr/Th µs
kV (charge voltage)
kV (charge voltage) |
EN 61000-4-5 |
- |
B |
| 4.4 |
Voltage dips |
30
10
60
100
60
1000 |
% reduction
ms
% reduction
ms
% reduction
ms |
EN 61000-4-11 |
See note 3.
Voltage shift at zero crossing |
B C
C |
| 4.5 |
Voltage interruptions |
>95 %
5000 |
% reduction
ms |
EN 61000-4-11 |
See note 3. |
C |
 | NOTE 1: The test level can be defined as the equivalent
current into a 150 ohm load. |
 | NOTE 2: Except for the ITU broadcast frequency band: 47 MHz -
68 MHz where the level shall be 3 V. |
 | NOTE 3: Applicable only to
input ports. |
Immunity - Functional earth ports
| 5 |
Environmental
Phenomena |
Test
Specification |
Units |
Basic
Standard |
Remarks |
Performance
Criteria |
| 5.1 |
Radio-frequency
common mode. |
0.15-80
10
80 |
MHz
V (rms, unmodulated)
%AM (1kHz) |
EN 61000-4-6 |
See notes 1 and
2.
The test level specified is rms value of the unmodulated carrier. |
A |
| 5.2 |
Fast transients |
± 1
5/50
5 |
kV (peak)
Tr/Th ns
Rep. frequency kHz |
EN 61000-4-4 |
See note 3. |
B |
 | NOTE 1: The test level can be defined as the equivalent
current into a 150 ohm load. |
 | NOTE 2: Except for the ITU broadcast frequency band: 47 MHz -
68 MHz where the level shall be 3 V. |
 | NOTE 3:
Applicable only to ports interfacing with cables whose total length according
to the manufacturers functional specification may exceed 3 m. |

|