Home Who? Contact Us Feedback Contents Search Test Plan

EN 61000-6-2
EN 61000-6-1 EN 61000-6-2

 

Following is the requirements for EN 61000-6-2

Immunity - Enclosure port

1

Environmental
Phenomena

Test
Specification

Units

Basic
Standard

Remarks

Performance
Criteria

1.1 Radio-frequency
electromagnetic field.
Amplitude Modulated.
80-1000
10
80
MHz
V/m (unmodulated, rms)
%AM (1kHz)
EN 61000-4-3 See note 1. The test level specified is prior to modulation. A
1.2 Power-frequency
magnetic field.
50
30
Hz
A(rms)/m
EN 61000-4-8 See note
2 and 3
A
1.3 Electrostatic discharge. ± 4 Contact
discharge

± 8 Air
discharge

kV (charge voltage)

kV (charge voltage)

EN 61000-4-2 See basic standard for applicability of contact and/or air discharge test. B

B

bulletNOTE 1: Except for the ITU broadcast frequency bands: 87 MHz - 108 MHz, 174 MHz - 230 MHz, and 470 MHz - 790 MHz where the level shall be 3 V/m.
bulletNOTE 2: Applicable only to apparatus containing devices susceptible to magnetic fields, such as Hall elements, electrodynamic microphones, magnetic field sensors, etc.
bullet

NOTE 3: For CRTs the acceptable jitter depends upon the character size and is computed for a test level of 1A/m as follows:
jitter (mm) = (3 x character size (mm) + 1)/40.
As jitter is linearly proportional to the magnetic field strength, tests can be carried out at other test levels extrapolating the maximum jitter level appropriately.

Immunity - Signal ports

2

Environmental
Phenomena

Test
Specification

Units

Basic
Standard

Remarks

Performance
Criteria

2.1 Radio-frequency
common mode.
0.15-80
10
80
MHz
V (rms, unmodulated)
%AM (1kHz)
EN 61000-4-6 See notes 1, 2 & 3.
The test level specified is rms value of the unmodulated carrier.
A
2.2 Fast transients ± 1
5/50
5
kV (peak)
Tr/Th ns
Rep. frequency kHz
EN 61000-4-4 See note 3.
Capacitive clamp used.
B
2.3 Surges
line-to-earth
1.2/50 (8/20)
± 1
Tr/Th us
kV
EN 61000-4-5 See notes 4 and 5 B
bulletNOTE 1: The test level can be defined as the equivalent current into a 150 ohm load.
bulletNOTE 2: Except for the ITU broadcast frequency band: 47 MHz - 68 MHz where the level shall be 3 V.
bullet

NOTE 3: Applicable only to ports interfacing with cables whose total length according to the manufacturers functional specification may exceed 3 m.

bullet

NOTE 4: Applicable only to ports interfacing with cables whose total length according to the manufacturers functional specification may exceed 30 m.

bullet

NOTE 5: Where normal functioning cannot be achieved because of the impact of the CDN on the EUT, this test is not required.

Immunity - Input and output DC power ports

3

Environmental
Phenomena

Test
Specification

Units

Basic
Standard

Remarks

Performance
Criteria

3.1 Radio-frequency
common mode.
0.15-80
10
80
MHz
V (rms, unmodulated)
%AM (1kHz)
EN 61000-4-6 See notes 1 and 2.
The test level specified is rms value of the unmodulated carrier.
A
3.2 Fast transients ± 2
5/50
5
kV (peak)
Tr/Th ns
Rep. frequency kHz
EN 61000-4-4 See note 3. B
3.3 Surges
line-to-earth
line-to-line
1.2/50 (8/20)
± 0.5
± 0.5
Tr/Th us
kV
kV
EN 61000-4-5 See note 3. B
bulletNOTE 1: The test level can be defined as the equivalent current into a 150 ohm load.
bulletNOTE 2: Except for the ITU broadcast frequency band: 47 MHz - 68 MHz where the level shall be 3 V.
bullet

NOTE 3: Not applicable to input ports intended for connection to a battery or a rechargeable battery which must be removed or disconnected from the apparatus for recharging. Apparatus with a DC power input port intended for use with an AC-DC power adapter shall be tested on the AC power input of the AC-DC power adapter specified by the manufacturer or where none is so specified, using a typical AC-DC power adapter. The test is applicable to DC power input ports intended to be permanently connected to cables less than 10 m in length.

Immunity - Input and output AC power ports

4

Environmental
Phenomena

Test
Specification

Units

Basic
Standard

Remarks

Performance
Criteria

4.1 Radio-frequency
common mode.
0.15-80
10
80
MHz
V rms
%AM (1kHz)
EN 61000-4-6 See note 1 and 2.
The test level specified is the rms value of the unmodulated carrier.
A
4.2 Fast transients ± 2
5/50
5
kV (charge voltage)
Tr/Th ns
Rep. frequency kHz
EN 61000-4-4 - B
4.3 Surges
line to earth
line to line
1.2/50 (8/20)
± 2
± 1
Tr/Th µs
kV (charge voltage)
kV (charge voltage)
EN 61000-4-5 - B
4.4 Voltage dips 30
10

60
100

60
1000
% reduction
ms

% reduction
ms

% reduction
ms
EN 61000-4-11

See note 3.
Voltage shift at zero crossing

B

C

C

4.5 Voltage interruptions >95 %
5000
% reduction
ms
EN 61000-4-11 See note 3. C
bulletNOTE 1: The test level can be defined as the equivalent current into a 150 ohm load.
bulletNOTE 2: Except for the ITU broadcast frequency band: 47 MHz - 68 MHz where the level shall be 3 V.
bulletNOTE 3: Applicable only to input ports.

Immunity - Functional earth ports

5

Environmental
Phenomena

Test
Specification

Units

Basic
Standard

Remarks

Performance
Criteria

5.1 Radio-frequency
common mode.
0.15-80
10
80
MHz
V (rms, unmodulated)
%AM (1kHz)
EN 61000-4-6 See notes 1 and 2.
The test level specified is rms value of the unmodulated carrier.
A
5.2 Fast transients ± 1
5/50
5
kV (peak)
Tr/Th ns
Rep. frequency kHz
EN 61000-4-4 See note 3. B
bulletNOTE 1: The test level can be defined as the equivalent current into a 150 ohm load.
bulletNOTE 2: Except for the ITU broadcast frequency band: 47 MHz - 68 MHz where the level shall be 3 V.
bulletNOTE 3: Applicable only to ports interfacing with cables whose total length according to the manufacturers functional specification may exceed 3 m.

Back ] Up ]

Send mail to web@atlasce.com with questions or comments about this web site.
Last modified: May 09, 2008