EN 61000-6-4
EN 61000-6-3 EN 61000-6-4

 

Following is the requirements for EN 61000-6-4

Emission

Port

Frequency range

Limits

Basic
Standard

Applicability note

Remarks

Enclosure
30-230 MHz 30 dB(µV/m) quasi peak,
measured at 30 m distance
EN 55011 See Note 1 May be measured at 10 m distance using the limits increased by 10 dB if the provisions of EN 55011 are met
230-1000 MHz 37 dB(µV/m) quasi peak,
measured at 30 m distance
AC Mains

 

0.15-0.5 MHz 79 dB(µV) quasi peak
66 dB(µV) average
EN 55011 See Note 2
See Note 3
-
0.5-5 MHz 73 dB(µV) quasi peak
60 dB(µV) average
5-30 MHz 73 dB(µV) quasi peak
60 dB(µV) average
bulletNOTE 1: In situ measurements are excluded from this standard.
bullet

NOTE 2: Impulse noise (clicks) which occurs less than 5 times per minute is not considered. For clicks appearing more often than 30 times per minute the limit apply. For clicks appearing between 5 and 30 times per minute, a relaxation of the limits is allowed of 20 log 30/N dB (where N is the number of clicks per minute). Criteria for separated clicks may be found in EN 55014.

bullet

NOTE 3: Applies only to apparatus operating at less than 1000 VrmsAC.