EN55024:1998
CE Mark Info Generic Emissions Generic Immunity EN55014-1 EN55024:1998 EN 55103

(dop) 1999-02-01 This is the date when this standard was published in the Official Journal of the European Communities and may be used for demonstrating conformity with the EMC Directive.
(dow) 2001-07-01 This is the date when all conflicting or previous standards are withdrawn and this standard must be used.

Following is the requirements for EN 55024:1998

Table 1 - Immunity, enclosure port

 

Environmental phenomenon

Test specification

Units

Basic Standard

Remarks

Performance criterion

1.1 Power-frequency magnetic field 50

1

Hz

A/m (r.m.s.)

IEC 61000-4-8 See 1) A

See annex B of EN 55024

1.2 Radio-frequency electromagnetic field

Amplitude modulation

80 – 1000

3

80

MHz

V/m (unmodulated, r.m.s.)

% AM (1 kHz)

IEC 61000-4-3 The test level specified is prior to modulation

See 2)

A
1.3 Electrostatic discharge 4 (Contact discharge)

8 (Air discharge)

kV (charge voltage)

kV (charge voltage)

IEC 61000-4-2   B
1) Applicable only to equipment containing devices susceptible to magnetic fields, such as CRT monitors, Hall elements, electrodynamic microphones, magnetic field sensors, etc.

2) The frequency range is scanned as specified. However, when specified in annex A, an additional comprehensive functional test shall be carried out at a limited number of frequencies. The selected frequencies are: 80, 120, 160, 230, 434, 460, 600, 863 and 900 MHz (± 1%).

 

Table 2 - Immunity, signal ports and telecommunication ports

 

Environmental phenomenon

Test specification

Units

Basic Standard

Remarks

Performance criterion

2.1 Radio-frequency continuous conducted 0.15 - 80

3

80

MHz

V (unmodulated, r.m.s.)

% AM (1 kHz)

IEC 61000-4-6 See 1) and 3) A
2.2 Surge

Line to ground

1

1.2/50 (8/20)

kV (peak)

Tr/Th m s

IEC 61000-4-5 See 2) and 4) B
2.3 Fast transients 0.5

5/50

5

kV (peak)

Tr/Th ns

kHz repetition frequency

IEC 61000-4-4 See 3) B
1) The frequency range is scanned as specified. However, when specified in annex A, an additional comprehensive functional test shall be carried out at a limited number of frequencies. The selected frequencies for conducted tests are: 0.2, 1, 7.1, 13.56, 21, 27.12, and 40.68 MHz (± 1%).

2) Applicable only to ports which according to the manufacturer’s specification may connect directly to outdoor cables.

3) Applicable only to cables which according to the manufacturer’s specification supports communication on cable lengths greater than 3m.

4) Where normal functioning cannot be achieved because of the impact of the CDN on the EUT, no test shall be required.

 

Table 3 - Immunity, input d.c. power port (excluding equipment marketed with a a.c./d.c. power converter)

(if d.c. power is fed on conductors included in signal cables, then the requirements of 2.1 – 2.3 only apply to this cable)

 

Environmental phenomenon

Test specification

Units

Basic Standard

Remarks

Performance criterion

3.1 Radio-frequency continuous conducted 0.15 - 80

3

80

MHz

V (unmodulated, r.m.s.)

% AM (1 kHz)

IEC 61000-4-6 See 1) A
3.2 Surge 0.5

1.2/50 (8/20)

kV (peak)

Tr/Th m s

IEC 61000-4-5 Test applied lines to earth (ground) See 2) B
3.3 Fast transients 0.5

5/50

5

kV (peak)

Tr/Th ns

kHz repetition frequency

IEC 61000-4-4 See 3) B
1) The frequency range is scanned as specified. However, when specified in annex A, an additional comprehensive functional test shall be carried out at a limited number of frequencies. The selected frequencies for conducted tests are: 0.2, 1, 7.1, 13.56, 21, 27.12, and 40.68 MHz (± 1%).

2) Applicable only to ports which according to the manufacturer’s specification may connect directly to outdoor cables.

 

Table 4 - Immunity, input a.c. power ports (including equipment marketed with a separate a.c./d.c. power converter)

 

Environmental phenomenon

Test specification

Units

Basic Standard

Remarks

Performance criterion

4.1 Radio-frequency continuous conducted 0.15 - 80

3

80

MHz

V (unmodulated, r.m.s.)

% AM (1 kHz)

IEC 61000-4-6 See 1) A
4.2 Voltage dips >95

0.5

% reduction

period

EN 61000-4-11 See 2) B
30

25

% reduction

period

C
4.3 Voltage interruptions >95

250

% reduction

period

EN 61000-4-11 See 2) C
4.4 Surges 1.2/50 (8/20)

1 line to line

2 line to earth (ground)

Tr/Th m s

kV (peak)

kV (peak)

IEC 61000-4-5 See 3) B
4.5 Fast transients 1.0

5/50

5

kV (peak)

Tr/Th ns

kHz repetition frequency

IEC 61000-4-4   B
1) The frequency range is scanned as specified. However, when specified in annex A, an additional comprehensive functional test shall be carried out at a limited number of frequencies. The selected frequencies for conducted tests are: 0.2, 1, 7.1, 13.56, 21, 27.12, and 40.68 MHz (± 1%).

2) Changes to occur at 0 degree crossover point of the voltage waveform.

3) When the manufacturer specifies protection measures and it is impractical to simulate these measures during the tests, then the applied test levels shall be reduced to 0.5 kV and 1 kV..