Phenomena |
Environments |
E1 |
E2 |
E3 |
E4 |
E5 |
1
Method A
EN 55022 clause 10
(note 1 & 5)
Method B
EN 55022 clause 5.5
(note 1) |
Method A
30-230 MHz 30 dB(m V/m) at 10 m
230-1000 MHz 37 dB(m V/m) at 10 m |
Method A
30-230 MHz 30 dB(m V/m) at 30 m
230-1000 MHz 37 dB(m V/m) at 30 m |
Method B
(alternatively if the largest dimension is less than 1m)
30-300 MHz 45-55 dB(pW) quasi-peak
30-300 MHz 35-45 dB(pW) average
300-1000 MHz (under consideration)
(note 6) |
Method B
30-300 MHz 55-65 dB(pW) quasi-peak
30-300 MHz 45-55 dB(pW) average
300-1000 MHz (under consideration)
(note 6) |
2
EN 55103-1 annex A (note 2 & 7) |
50 Hz to 500 Hz 4-0.4 A/m at 10 cm
500 Hz to 50 kHz 0.4 A/m at 10 cm |
No limits
Measurements not required |
3
EN 55103-1 annex A (note 3 & 7) |
50 Hz to 5 kHz 1-0.01 A/m at 1 m
5 kHz to 50 kHz 0.01 A/m at 1 m |
No limits
Measurements not required |
4
EN 61000-3-2 or
EN 61000-3-4 |
Refer to basic standard (note 5) |
5
EN 61000-3-3 or
EN 61000-3-5 |
Refer to basic standard (note 5) |
6
EN 55022
(note 5) |
0.15-0.5 MHz
66-56 dB(m V) quasi-peak 56-46 dB(m
V) average
0.5-5 MHz (note 7)
56 dB(m V) quasi-peak 46 dB(m V)
average
5-30 MHz
60 dB(m V) quasi-peak 50 dB(m V)
average (note 8) |
0.15-0.5 MHz
76 dB(m V) quasi-peak
66 dB(m V) average (note 7)
0.5-30 MHz
73 dB(m V) quasi-peak
60 dB(m V) average (note 8) |
7
EN 55014 |
Refer to basic standard clause 4.2
(note 4 & 5) |
8
EN 55103-1 annex B |
Peak inrush current:
the manufacturer shall state the peak inrush current in the documentation for the
purchaser/user |
9
EN 55013 |
Refer to basic standard table 2
(note 9) |
10
EN 55022 annex C.1.2 (note 5) |
0.15-0.5 MHz
50-40 dB(m A) quasi-peak 40-30 dB(m
A) average (note 7)
0.5-30 MHz
40 dB(m A) quasi-peak 30 dB(m A)
average |
0.15-0.5 MHz
63-53 dB(m A) quasi-peak
53-43 dB(m A) average (note 7)
0.5-30 MHz
53 dB(m A) quasi-peak
43 dB(m A) average |